|
|
By Deepesh Divakaran, on January 25th, 2012
 Does that title sound funny? Can you update your Primary Keys of a record in a table too? Ofcourse you can, SQL does allow it. But does that work in an ERP? Yes ERP’s are supposed to keep their data integrity well, and secure it too. But in JD Edwards you have an option to [...] . . . → Read More: Update a Table’s Primary Keys from JDE
By Deepesh Divakaran, on December 13th, 2011
 The JD Edwards Demo installation has got even easier. Thanks to Oracle, who has brought in Oracle Universal Installer (OUI) to the scene. We have tested the installation on Windows XP, Vista and Windows 7 too (all 32bit versions, please do let know if it went well for 64bit OS’s). All of them work great. [...] . . . → Read More: JD Edwards EnterpriseOne 9.0.2 Standalone Installation
By Satish Kanth, on December 1st, 2011
 These are the following steps to write messages to Work Center via the standard BSFN. 1. Initialize the PPAT pointer (B0100025) 2. Set/indicate the order level errors ( Order no/TYP/CO ) (B0100011) 3. Process the errors to WC 4. Release the PPAT Pointer Eg: 1. Write in the Initialize section F01131 Edit JDEM Error Message [...] . . . → Read More: Write to JDE Work Center
By Krishna Nambiar, on October 26th, 2011
 This is the proposed interface for E1 tools 9.1 demoed at the OOW. It does look as if Oracle is indeed giving importance to maintain E1 as an competitive ERP solution. . . . → Read More: The New EnterpriseOne 9.1 Interface
By Muthu Kumar Lakshmanan, on September 22nd, 2011
 I created a custom table. When creating a new table, when is it required to Generate the Table? Also under what circumstances is it necessary to run the Generate Header File option? A report using the custom table seems able to write to a table only when Generate Header File is done. Solution When creating [...] . . . → Read More: Information on Table Design Aid
By Deepesh Divakaran, on August 13th, 2011
 *The article is rated Must read for Beginners/Novice There has been many a confusion with JDE freshers, on how to use the Internal Data selection, or called as ER Data selection and how to use them. Following are our assumptions for the scenarios (for REPORT DESIGN AID (RDA)) – There’s a Processing Option which takes inputs of [...] . . . → Read More: How Event Rule Dataselection Works in JDE Tools
By Muthu Kumar Lakshmanan, on August 11th, 2011
 All tables used by Object Management Workbench are located in the SYSTEM data source (e.g.: System – 812). OMW uses the following tables: F98210 – Logging Header Contains header information including the project, object type, object name, time stamps, path codes, data sources, locations and action type. F98211 – Logging Detail Contains detailed information on [...] . . . → Read More: Tables used by Object Management Workbench (OMW)
|
|
Recent Comments